PESQ and MOS give a call-quality score a caller can read

Jonas Petrak, Research writer (AI-assisted) ·

You can use PESQ as the objective core of a call-quality test: play a known speech file from one end of a phone line, record what arrives at the other end, and score the difference. The MOS figure then gives your team a scale they can read without knowing the signal processing behind it. Neither number is a customer's opinion, but together they show what a caller would hear.

What PESQ actually compares

PESQ is a full-reference method. It was standardized as ITU-T P.862 in 2001. It works by comparing the degraded signal at the listener side with the original reference signal from the talker side, sample by sample [1]. That reference is what makes it objective: you are not asking a model to guess what the original sounded like.

Two practical rules follow. First, feed it speech, not tones or noise. Many telecom systems are optimized for speech and respond unpredictably to other signals, so the test file should be real voice samples, as the application guide in P.862.3 recommends [1]. Second, plan for the licence. PESQ is used by phone manufacturers, equipment vendors and operators, and its use requires a licence [1].

The trade-off is that full-reference measurement needs the original file. That makes it suited to dedicated tests in live networks, such as drive tests. It cannot score a live customer call you have no reference for. Full-reference methods deliver the highest accuracy and repeatability [1], so the no-reference alternative, ITU-T P.563, gives up some of that accuracy in exchange for not needing the original [1].

How the score becomes a MOS

PESQ produces a raw number on a 1 to 4.5 scale, and MOS is the version a person can read at a glance. Cyara says MOS values are derived from PESQ scores through a statistical mapping, so that they line up with what listeners report [3]. Its platform reports both numbers side by side [3].

Cyara also groups PESQ scores into bands by how hard the listener has to work. A score from 3.80 to 4.50 means a listener can relax with no effort, while 2.00 to 2.39 means considerable effort [3]. For a contact-centre team, the threshold that matters is where callers start asking to repeat themselves. Cyara links scores of 2.00 to 2.79 to phrases such as "Could you repeat that?", and says those calls can end in abandonment [3].

Be careful when you compare MOS values across tests. A MOS is a mean of listener ratings on a fixed scale, and its meaning depends on how that test was run: the people who rated, the clips they heard, and the scale they used [2]. The MOS literature also debates whether averaging ordinal category ratings is valid at all, and suggests the median as the safer summary [2]. In practice, keep one test design for a trend line, and do not set a benchmark from another vendor's study.

Where the scores fit in the framework

PESQ is a full-reference measure. It needs the original file and the degraded copy, and it compares them sample by sample [1]. In a phone test, that means the reference is played on the talker side and captured on the listener side [3]. Put the measurement at the listener end, use the same reference files on every run, and log each PESQ score next to the MOS it maps to. PESQ reports on a 1 to 4.5 scale, with higher values meaning better quality [3]. A MOS is a mean of listener ratings on a predefined scale, usually 1 to 5 [2]. The two numbers answer the same question on different scales, so record both.

Keep the subjective side in view. A MOS comes from human ratings in a subjective test, although it can also be estimated algorithmically [2]. Where you can run a listening panel on the same clips, compare its ratings with your calibrated scores. If the two diverge, the calibration needs checking before you trust the numbers. Also remember that a MOS built from categorical ratings is an ordinal scale, and the median is the statistically sound summary, not the mean [2].

If you run a contact centre, start small: one reference file, a fixed list of destination numbers, and a weekly run. If you run a network, do the same with a dedicated test line on each carrier you use. Compare the same reference across runs rather than reading one score on its own. The sources here do not give a method for reading those trends, so treat the trend comparison as your own working rule until you have enough runs to set a baseline.

Sources

  1. Perceptual Evaluation of Speech Quality - Wikipedia
  2. Mean opinion score - Wikipedia
  3. What is PESQ? — Cyara

More articles